40WATT, BRS40 SERIES AC/DC
Dual/Triple Output, Open Frame
Selection Guide
Description
- Universal Input 90-264Vac
- 2" x 4" Footprint
- Efficiency at 75% typical
- Conductive EMI meets CISPR/FCC Class B
FEATURES
- Input Characteristics
- Voltage Range 90-264Vac,120-370Vac
- Frequency 47-440Hz
- Inrush current 50A Max.at 264Vac
- Input current 1A Max.at 115Vac
- Isolation(Input to Output) 4242Vdc
- Leakage current 0.5mA Max
Output Characteristics
- Hold-up time 20mS typ.@115Vac
- Short circuit with over-load protection
- All Outputs (Auto Recovery)
- Over Voltage Protection:3.6-4.6V, 5.7-6.7V ON V1 (3.3V-5V) 120-140% (V2) 12V,15V,24V
- Operating temperature from 0C to 50C
- Storage temperature from 20C to 85C
- Adjustment range ±10%
- Typical at nominal input, rated load at 25 degrees unless other specified.