ICIGB100-130Watt AC-DC OPEN FRAME POWER CONVERTER
SINGLE & MULTIPLE OUTPUTS

Selection Guide
FEATURES
- Small size 3.00" x 5.00" x 1.28"
- Greater than 80% Efficiency
- 100-130W with Convection Cooling
- Single & Multiple Outputs
- Open Frame Converter
- Wide Input Voltage 90 to 264VAC, 47 to 63Hz.
- Internal EMI filter
- Power Factor Correction
- Output Voltage Protection/Crowbar design
- Input Surge Current
- Over Voltage and Overload Protection
| Parameters | Conditions | Min | Typical | Max | Units |
|---|---|---|---|---|---|
| AC Input Voltage | 90 | 100-240 | 264 | ||
| Input Frequency | 47 | 50/60 | 63 | Hz | |
| DC Input Voltage | 127 | 370 | Vdc | ||
| Inrush Current | 115Vac/230Vac | 30/60 | A |
Output Specifications:
| Set Point Accuracy | V1 +/-1%,V2 and V3 +/-5%, Measured at 60% Load |
| Output Power | To 130Watt |
| Minimum Load | No Minimum Load Required (Note 1) |
| Line Regulation | +/-0.5% for Nominal Line +/-10% |
| Load Regulation | +/-1%, +/-5% for all secondary Outputs on Multiple Output Models |
| Tolerance | +/-1 |
| Ripple & Noise | +/-1, Mvp-p |
| Transient Response | 4% max deviation, 500 uS Recovery Time for a 25% Load Change |
| Temperature | O.5% |
General Specifications:
| Efficiency Typical | >80% Nominal Line full load |
| Power Density | 6.3 Win3 single Output Models |
| MTBF | 100,000 Hours |
| Size | 3.00 x 5.00 x 1.28"/1.35" for multi-output |
| Weight | 300 grams |
| Operating Temperature | Minimum: -20C, Maximum: +70C |
| Storage Temperature | Minimum: -45C, Maximum: +85C |
| Isolation Voltage | 3000VAC Input to Output |
| Isolation Voltage | 1500VAC Input to Ground |
| Isolation Voltage | 500VAC Output to Ground |
| Safety & EMC | Meets UL 1950 |
Coefficient Specifications:
| Hold Up time | Typical/16, Units/mS |
| Remote sense | On V1 only, compensates for 0.5V lead drop |
| Overvoltage | 115% to 140% Protection recycle input to reset |
| Overcurrent | 120%-150% Foldback |
| Protection | With auto recovery |
Notes:
- .20% minimum load required on V1 to maintain stated regulation for auxiliary rails.
- Load regulation of auxiliaries is defined over the range of 60% of rated output +/-40%.
- Ripple & Noise is measured by using 20 MHz bandwith, each output terminated with a 0.47 uF capacitor and a 47 uF electrolytic capacitor at rated load and nominal line.
Notes:1.Input connector mates with Molex housing 09-50-3051 and Molex 2478 series crimp terminal.
2.Output connector mates with Molex housing 09-50-3101 and Molex 2478 series crimp terminal.
| TB2 | Models | |||
|---|---|---|---|---|
| Pins | PS05 | PS12, 15, 24 48 | PT31 | PT30 |
| 1 | +V | +V | +5V | +3.3V |
| 2 | +V | +V | +5V | +3.3V |
| 3 | +V | +V | +5V | +3.3V |
| 4 | +V | RET | RET | RET |
| 5 | RET | RET | RET | RET |
| 6 | RET | RET | RET | RET |
| 7 | RET | N/A | RET | RET |
| 8 | RET | N/A | +12V | +5V |
| 9 | N/A | N/A | +12V | +5V |
| 10 | N/A | N/A | N/A | +12V |
CALL: 508-580-8515, EXT 1